CF-04 Weight of evidence assessment (EFSA (European Food Safety Authority) assemble, weigh and integrate; US EPA weight of evidence)
Assembles lines of evidence of different kinds, weighs each for reliability and relevance and integrates them into one conclusion with an uncertainty statement.
What it does
Assembles lines of evidence of different kinds, weighs each for reliability and relevance and integrates them into one conclusion with an uncertainty statement. Artefact: a table that weighs each line. Read whether two reports of one study were counted as two lines.
When to use it
Use when the findings of two or more techniques must be turned into stated conclusions.
When it does not fit
Fits risk or hazard questions whose evidence cannot be pooled. Double counting of dependent sources is documented for data fusion (IS-06) but not for this method.
Result format
The result is a table that weighs each line.
Requirements on the material
| Property | Requirement type | Requirement |
|---|---|---|
| Appraises source credibility | Applies in some cases | no |
Not restricted on: Structure, Content type, Unit of analysis, Variable types, Time structure, How the sample was chosen, Level of detail available, Number of sources, Whether sources can be joined, Amount of material, Known data problems, Producer interest, Source dependence, Origin, Document genre, Language, Personal information, Security classification, Licence.
| Minimum material | The findings of two or more techniques. A report to examine. Outside material: reference structure. |
|---|---|
| Additional sources needed | reference structure |
| Not for (rules) | none |
| Not for (text) | Counts two reports of one study as two lines of evidence. |
Choosing and ordering
| Kind of technique | Conclusion technique, runs in step 7 |
|---|---|
| Phase tag | conclude |
| Other phase tags | conclude |
| Kind of finding | risk; contradiction |
| Question answered | how sure; what |
| Strongest statement it supports | Not applicable. It carries the strength of statement of the analysis techniques that ran. |
| Needs as input |
|
| Makes as output |
|
| Must exist first | None |
| Loop target | return to analyse |
Library checks by stakes
Each stakes level includes the checks of the level below it. Checks that need a person apply at high stakes only, so the process leaves them out at lower stakes (decision 38). Repeatability: judgement dependent.
| Stakes | Check | Person involved | Counts as a different method |
|---|---|---|---|
| exploratory | assumption and limitation statement | none | no |
| decision-informing | assumption and limitation statement | none | no |
| decision-informing | spot check | optional | no |
| high-stakes | assumption and limitation statement | none | no |
| high-stakes | spot check | optional | no |
| high-stakes | independent review | needed | no |
Failure modes and limits
| Model suitability | human judgement required |
|---|---|
| Typical model failure | Counts two reports of one study as two lines of evidence. |
| Error sources | language model; expert opinion |
| Certainty limits | The conclusion depends on the findings it combines. Certainty drops when the findings come from one technique, from the same material read the same way, or when a conflict between findings has no stated cause. |
Evidence and tag basis
Documented. The EFSA guidance defines weight of evidence assessment as a process in which evidence is integrated to determine the relative support for possible answers to a question. It has three steps: assembling the evidence into lines of evidence of similar type, weighing it, and integrating it. It names reliability, relevance and consistency as the three considerations for weighing. No test was found. (EFSA Scientific Committee 2017, guidance on weight of evidence; full text on PubMed Central)
Tag basis: input profile inference; selection inference; sequencing inference; robustness inference. All tag values are inference unless a source is named.